1300. R.L. Vereecken, W. Proesmans, “Results of endoscopic treatment for vesico-ureteric reflux,” Eur. Urol. 27(1995):76-79.

1301. P. Puri, M. Palanimuthu, L. Dass, “Endoscopic treatment of primary vesicoureteric reflux in infants by subureteric injection of polytetrafluoroethylene. A 9-year follow-up,” Eur. Urol. 27(1995):67-70.

1302. F. Simsek, O. Dillioglugil, Y. Ilker, A. Akdas, “Correction of primary and secondary vesicoureteral reflux by subureteric Teflon injection,” Int. Urol. Nephrol. 27(1995):51-56.

1303. P.D. Hughes, “Ureteric reflux in adults and children treated exclusively by endoscopic Teflon injection: a 10-year experience,” Aust. N. Z. J. Surg. 69(December 1999):856-859.

1304. J.M. Dubernard, “Endoscopic treatment of vesicoureteral reflux prior to renal transplantation,” Transpl. Int. 5(September 1992):231-233.

1305. P. Giannotti, D. Pistolesi, M.G. Cuttano, “Endoscopic treatment of vesico-renal reflux with teflon: personal experience among adults and neurologic patients,” Arch. Ital. Urol. Androl. 69(February 1997):47-53 (Suppl 1). In Italian.

1306. F. Frezard, C. Santaella, P. Vierling, J.G. Riess, “Permeability and stability in buffer and in human serum of fluorinated phospholipid-based liposomes,” Biochim. Biophys. Acta 1192(1 June 1994):61-70.

1307. C. Guedj, B. Pucci, L. Zarif, C. Coulomb, J.G. Riess, A.A. Pavia, “Vesicles and other supramolecular systems from biocompatible synthetic glycolipids with hydrocarbon and/or fluorocarbon chains,” Chem. Phys. Lipids 72(8 August 1994):153-173.

1308. F. Guillod, J. Greiner, J.G. Riess, “Vesicles made of glycophospholipids with homogeneous (two fluorocarbon or two hydrocarbon) or heterogeneous (one fluorocarbon and one hydrocarbon) hydrophobic double chains,” Biochim. Biophys. Acta 1282(25 July 1996):283-292.

1309. L. Clary, V. Ravily, C. Santaella, P. Vierling, “Transmembrane pH-driven Na+ permeability of fluorinated phospholipid-based membranes,” J. Controlled Release 51(12 February 1998):259-267.

1310. F. Becmeur, S. Geiss, S. Laustriat, J. Bientz, L. Marcellin, P. Sauvage, “History of Teflon,” Eur. Urol. 17(1990):299-300.

1311. S. Laustriat, S. Geiss, F. Becmeur, J. Bientz, L. Marcellin, P. Sauvage, “Medical history of Teflon,” Eur. Urol. 17(1990):301-303.

1312. H. Dodat, “Endoscopic treatment of vesicorenal reflux in children,” Arch. Pediatr. 1(January 1994):93-100. In French.

1313. C.Y. Chen, N.Y. Hsu, P.C. Kwan, C.P. Hsu, J.Y. Hsia, “Change of lower esophageal sphincter pressure in rabbits by Teflon injection,” Chung Hua I Hsueh Tsa Chih (Taipei) 58(August 1996):79-83.

1314. J.M. Legeais, L.P. Werner, G. Legeay, B. Briat, G. Renard, “In vivo study of a fluorocarbon polymer-coated intraocular lens in a rabbit model,” J. Cataract Refract. Surg. 24(March 1998):371-379.

1315. G. Clarotti, F. Schue, J. Sledz, A. Ait Ben Aoumar, K.E. Geckeler, A. Orsetti, G. Paleirac, “Modification of the biocompatible and haemocompatible properties of polymer substrates by plasma-deposited fluorocarbon coatings,” Biomaterials 13(1992):832-840.

1316. G. Geyer, “Materials for reconstruction of the middle ear,” HNO 47(February 1999):77-91. In German.

1317. R.S. Pinto, E. Robbins, D. Seidenwurm, “Thrombogenicity of Teflon versus copolymer-coated guidewires: evaluation with scanning electron microscopy,” AJNR Am. J. Neuroradiol. 10(March-April 1989):407-410.

1318. H. Tsuchida, B.L. Cameron, C.S. Marcus, S.E. Wilson, “Modified polytetrafluoroethylene: indium 111-labeled platelet deposition on carbon-lined and high-porosity polytetrafluoroethylene grafts,” J. Vasc. Surg. 16(October 1992):643-649, 649-650 (discussion).

1319. J. Couture, R. Guidoin, M. King, M. Marois, “Textile Teflon arterial prostheses: how successful are they?” Can. J. Surg. 27(November 1984):575-582.

1320. J.E. Field, “Appendix: Tables of Properties,” in J.E. Field, ed., The Properties of Natural and Synthetic Diamond, Academic Press, NY, 1992, pp. 667-699.

1321. B. Lindblad, A. Johansson, “125I-fibrinogen uptake on peripheral venous cannulas: a comparison between different cannula materials and coatings,” J. Biomed. Mater. Res. 21(January 1987):99-105.

1322. D.R. Absolom, W. Zingg, A.W. Neumann, “Protein adsorption to polymer particles: role of surface properties,” J. Biomed. Mater. Res. 21(February 1987):161-171.

1323. H.A. Wosten, F.H. Schuren, J.G. Wessels, “Interfacial self-assembly of a hydrophobin into an amphipathic protein membrane mediates fungal attachment to hydrophobic surfaces,” EMBO J. 13(15 December 1994):5848-5854.

1324. W. van der Vegt, H.C. van der Mei, H.A. Wosten, J.G. Wessels, H.J. Busscher, “A comparison of the surface activity of the fungal hydrophobin SC3p with those of other proteins,” Biophys. Chem. 57(January 1996):253-260.

1325. J. Carballo, C.M. Ferreiros, M.T. Criado, “Influence of blood proteins in the in vitro adhesion of Staphylococcus epidermidis to teflon, polycarbonate, polyethylene and bovine pericardium,” Rev. Esp. Fisiol. 47(December 1991):201-208.

1326. G.B. Koveker, W.E. Burkel, L.M. Graham, T.W. Wakefield, J.C. Stanley, “Endothelial cell seeding of expanded polytetrafluoroethylene vena cava conduits: effects on luminal production of prostacyclin, platelet adherence, and fibrinogen accumulation,” J. Vasc. Surg. 7(April 1988):600-605.

1327. D. Kiaei, A.S. Hoffman, T.A. Horbett, K.R. Lew, “Platelet and monoclonal antibody binding to fibrinogen adsorbed on glow-discharge-deposited polymers,” J. Biomed. Mater. Res. 29(June 1995):729-739.

1328. J.L. Bohnert, B.C. Fowler, T.A. Horbett, A.S. Hoffman, “Plasma gas discharge deposited fluorocarbon polymers exhibit reduced elutability of adsorbed albumin and fibrinogen,” J. Biomater. Sci. Polym. Ed. 1(1990):279-297.

1329. P.B. van Wachem, C.M. Vreriks, T. Beugeling, J. Feijen, A. Bantjes, J.P. Detmers, W.G. van Aken, “The influence of protein adsorption on interactions of cultured human endothelial cells with polymers,” J. Biomed. Mater. Res. 21(June 1987):701-718.

1330. D. Kiaei, A.S. Hoffman, T.A. Horbett, “Tight binding of albumin to glow discharge treated polymers,” J. Biomater. Sci. Polym. Ed. 4(1992):35-44.

1331. R.C. Eberhart, M.E. Lynch, F.H. Bilge, H.A. Arts, “Effects of fluid shear and temperature on protein adsorption on teflon surfaces,” Trans. Am. Soc. Artif. Intern. Organs 26(1980):185-193.

1332. R.C. Eberhart, L.D. Prokop, J. Wissenger, M.A. Wilkov, “Observation of albumin deposits on teflon surfaces,” Trans. Am. Soc. Artif. Intern. Organs 23(1977):134-140.

1333. V. Balasubramanian, N.K. Grusin, R.W. Bucher, V.T. Turitto, S.M. Slack, “Residence-time dependent changes in fibrinogen adsorbed to polymeric biomaterials,” J. Biomed. Mater. Res. 44(March 1999):253-260.

1334. P.W. Caessens, H.H. De Jongh, W. Norde, H. Gruppen, “The adsorption-induced secondary structure of beta-casein and of distinct parts of its sequence in relation to foam and emulsion properties,” Biochim. Biophys. Acta 1430(10 February 1999):73-83.

1335. T. Zoungrana, G.H. Findenegg, W. Norde, “Structure, Stability, and Activity of Adsorbed Enzymes,” J. Colloid Interface Sci. 190(15 June 1997):437-448.

1336. A.W. Vermeer, M.G. Bremer, W. Norde, “Structural changes of IgG induced by heat treatment and by adsorption onto a hydrophobic Teflon surface studied by circular dichroism spectroscopy,” Biochim. Biophys. Acta 1425(16 September 1998):1-12; A.W. Vermeer, W. Norde, “CD spectroscopy of proteins adsorbed at flat hydrophilic quartz and hydrophobic Teflon surfaces,” J. Colloid Interface Sci. 225(15 May 2000):394-397; A.W. Vermeer, C.E. Giacomelli, W. Norde, “Adsorption of IgG onto hydrophobic teflon. Differences between the F(ab) and F(c) domains,” Biochim. Biophys. Acta 1526(3 April 2001):61-69.

1337. P. Boivin, R.K. Kobos, S.L. Papa, W.H. Scouten, “Immobilization of perfluoroalkylated enzymes in a biologically active state onto Perflex support,” Biotechnol. Appl. Biochem. 14(October 1991):155-169.

1338. M.C.L. Maste, W. Norde, A.J.W.G. Visser, “Adsorption-Induced Conformational Changes in the Serine Proteinase Savinase: A Tryptophan Fluorescence and Circular Dichroism Study,” J. Colloid Interface Sci. 196(15 December 1997):224-230.

1339. M.C. Maste, H.A. Rinia, C.M. Brands, M.R. Egmond, W. Norde, “Inactivation of a subtilisin in colloidal systems,” Biochim. Biophys. Acta 1252(25 October 1995):261-268.

1340. P. Vermette, J. Thibault, S. Levesque, G. Laroche, “Lipid uptake across the wall of an expanded polytetrafluoroethylene vascular graft,” J. Biomed. Mater. Res. 48(1999):660-668.

1341. G. Berton, S. Gordon, “Superoxide release by peritoneal and bone marrow-derived mouse macrophages. Modulation by adherence and cell activation,” Immunology 49(August 1983):693-704.

1342. K. Kasahara, R.M. Strieter, S.W. Chensue, T.J. Standiford, S.L. Kunkel, “Mononuclear cell adherence induces neutrophil chemotactic factor/interleukin-8 gene expression,” J. Leukoc. Biol. 50(September 1991):287-295.

1343. R.H. Rigdon, “Inflammation associated with dacron and teflon: an experimental study in mice, rats and rabbits,” Tex. Rep. Biol. Med. 32(Summer 1974):535-551.

1344. R.J. Reid, D.F. Wilson, K.K. Chau, G.S. Heithersay, P.S. Heijkoop, “Tissue responses to Hydron, assessed by intramuscular implantation,” Int. Endod. J. 25(July 1992):199-204.

1345. R.E. Wilsnack, S.A. Bernadyn, “Blood compatibility of medical device materials as measured by lymphocyte function,” Biomater. Med. Devices Artif. Organs 7(1979):527-546.

1346. T.K. Issa, M.A. Bahgat, F.H. Linthicum Jr., “Tissue reaction to prosthetic materials in human temporal bones,” Am. J. Otol. 5(July 1983):40-43.

1347. H.D. Schulte, E. Sygula, M. Bourgeois, W. Pottgen, L. Seipel, “Severe mechanical haemolysis after correction of a partial atrioventricular canal,” Thoraxchir. Vask Chir. 26(April 1978):117-123. In German.

1348. G.L. Hines, T.T. Finnerty, E. Doyle, O.W. Isom, “Near fatal hemolysis following repair of ostium primum atrial septal defect,” J. Cardiovasc. Surg. (Torino) 19(January-February 1978):7-10.

1349. R.J. Reid, D.F. Wilson, K.K. Chau, G.S. Heithersay, P.S. Heijkoop, “Tissue responses to Hydron, assessed by intraosseous implantation,” Int. Endod. J. 25(July 1992):192-198.

1350. S.M. Bhambhani, O.R. Bolanos, “Tissue reactions to endodontic materials implanted in the mandibles of guinea pigs,” Oral Surg. Oral Med. Oral Pathol. 76(October 1993):493-501.

1351. N. Jensen, B. Lindblad, D. Bergqvist, “In vitro attachment of endothelial cells to different graft materials,” Eur. Surg. Res. 28(1996):49-54.

1352. M.P. Bobek, O. Sagher, “Aseptic meningitis caused by Teflon implantation for microvascular decompression. Case report,” J. Neurosurg. 90(January 1999):145-147.

1353. T. Fujimaki, K. Hoya, T. Sasaki, T. Kirino, “Recurrent trigeminal neuralgia caused by an inserted prosthesis: report of two cases,” Acta Neurochir. (Wien) 138(1996):1307-1309, 1310 (discussion).

1354. S.A. Makohliso, L. Giovangrandi, D. Leonard, H.J. Mathieu, M. Ilegems, P. Aebischer, “Application of Teflon-AF thin films for bio-patterning of neural cell adhesion,” Biosens. Bioelectron. 13(15 November 1998):1227-1235.

1355. S.K. Hunter, J.R. Scott, D. Hull, R.L. Urry, “The gamete and embryo compatibility of various synthetic polymers,” Fertil. Steril. 50(July 1988):110-116.

1356. L. Holy, M. Lopatarova, H. Kotrcova, J. Navratil, “Bloodless transfer of early bovine embryos in relation to the biological properties of the materials used,” Vet. Med. (Praha) 29(July 1984):401-409. In Czech.

1357. J.A. LaIuppa, T.A. McAdams, E.T. Papoutsakis, W.M. Miller, “Culture materials affect ex vivo expansion of hematopoietic progenitor cells,” J. Biomed. Mater. Res. 36(5 September 1997):347-359.

1358. T. Maetani, R. Miyoshi, Y. Nahara, Y. Kawazoe, T. Hamada, “Plaque accumulation on Teflon-coated metal,” J. Prosthet. Dent. 51(March 1984):353-357.

1359. A. Pascual, I. Garcia, E. Ramirez de Arellano, E.J. Perea, “Activity of sparfloxacin on Staphylococcus epidermidis attached to plastic catheters,” J. Antimicrob. Chemother. 36(August 1995):425-430.

1360. A.H. Hogt, J. Dankert, J. Feijen, “Adhesion of Staphylococcus epidermidis and Staphylococcus saprophyticus to a hydrophobic biomaterial,” J. Gen. Microbiol. 131(September 1985):2485-2491.

1361. A. Pascual, A. Fleer, N.A. Westerdaal, J. Verhoef, “Modulation of adherence of coagulase-negative staphylococci to Teflon catheters in vitro,” Eur. J. Clin. Microbiol. 5(October 1986):518-522.

1362. L.M. Wolford, “Temporomandibular joint devices: treatment factors and outcomes,” Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod. 83(January 1997):143-149.

1363. L.N. Estabrooks, C.E. Fairbanks, R.J. Collett, L. Miller, “A retrospective evaluation of 301 TMJ Proplast-Teflon implants,” Oral Surg. Oral Med. Oral Pathol. 70(September 1990):381-386.

1364. T.A. Dorsay, R.A. Youngberg, F.E. Orr, J. Mulrean, “Cine MRI in the evaluation of the Proplast-Teflon TMJ interpositional implant,” J. Comput. Assist. Tomogr. 19(September-October 1995):800-803.

1365. R. Chuong, M.A. Piper, T.J. Boland, “Recurrent giant cell reaction to residual Proplast in the temporomandibular joint,” Oral Surg. Oral Med. Oral Pathol. 76(July 1993):16-19.

1366. L.M. Wolford, D.A. Cottrell, C.H. Henry, “Temporomandibular joint reconstruction of the complex patient with the Techmedica custom-made total joint prosthesis,” J. Oral Maxillofac. Surg. 52(January 1994):2-10, 11 (discussion).

1367. L.G. Mercuri, “Considering total temporomandibular joint replacement,” Cranio 17(January 1999):44-48.

1368. M.J. Robinson, M. Nestor, A.M. Rywlin, “Pulmonary granulomas secondary to embolic prosthetic valve material,” Hum. Pathol. 12(August 1981):759-762.

1369. J. Weingarten, S.L. Kauffman, “Teflon embolization to pulmonary arteries,” Ann. Thorac. Surg. 23(April 1977):371-373.

1370. K.W. Walton, G. Slaney, F. Ashton, “Atherosclerosis in vascular grafts for peripheral vascular disease. Part 2. Synthetic arterial prostheses,” Atherosclerosis 61(August 1986):155-167.

1371. G.W. Bos, A.A. Poot, T. Beugeling, W.G. van Aken, J. Feijen, “Small-diameter vascular graft prostheses: current status,” Arch. Physiol. Biochem. 106(April 1998):100-115.

1372. N. Tanigawa, S. Sawada, M. Kobayashi, “Reaction of the aortic wall to six metallic stent materials,” Acad. Radiol. 2(May 1995):379-384.

1373. J. Hoevels, I. Ihse, “Percutaneous transhepatic insertion of a permanent endoprosthesis in obstructive lesions of the extrahepatic bile ducts,” Gastrointest. Radiol. 4(15 November 1979):367-377.

1374. A.M. van Berkel, J. van Marle, H. van Veen, A.K. Groen, K. Huibregtse, “A scanning electron microscopic study of biliary stent materials,” Gastrointest. Endosc. 51(January 2000):19-22.

1375. J. di Costanzo, B. Sastre, R. Choux, M. Kasparian, “Mechanism of thrombogenesis during total parenteral nutrition: role of catheter composition,” JPEN J. Parenter. Enteral Nutr. 12(March-April 1988):190-194.

1376. L.A. Lobes Jr., M.G. Grand, P.G. Rehkopf, B. Johnson, “Polytetrafluoroethylene in experimental retinal detachment surgery,” Ann. Ophthalmol. 13(August 1981):921-923.

1377. J.F. Korobelnik, F. D’Hermies, D. Ducourneau, J.M. Legeais, D. Chauvaud, T. Hoang-Xuan, G. Renard, “e-PTFE as scleral buckling episcleral implants: An experimental and histopathologic study,” J. Biomed. Mater. Res. 48(1999):807-813.

1378. J.M. Legeais, G. Renard, “Keratoprosthesis: study of an expanded polytetrafluoroethylene support,” J. Fr. Ophtalmol. 10(1987):425-433. In French.

1379. S. Shah, M. Rhatigan, R. Sampath, C. Yeoman, S. Sunderland, R. Brammer, B. Leatherbarrow, “Use of Proplast II as a subperiosteal implant for the correction of anophthalmic enophthalmos,” Br. J. Ophthalmol. 79(September 1995):830-833.

1380. J.J. Hurwitz, “Teflon tubes for stenting and bypassing the lacrimal drainage pathways,” Ophthalmic Surg. 20(December 1989):855-859.

1381. N. Bassi, V. Terribile, P. Callegari, A. Abbate, “Experimental effectiveness of a teflon prosthesis in the substitution of the trachea,” Acta Otorhinolaryngol. Ital. 5(July-August 1985):433-441. In Italian.

1382. S.H. Reuter, “The bivalve teflon nasal septal splint,” Trans. Am. Acad. Ophthalmol. Otolaryngol. 77(May-June 1973):ORL146-ORL148.

1383. G.M. Vercellotti, D.E. Hammerschmidt, P.R. Craddock, H.S. Jacob, “Activation of plasma complement by perfluorocarbon artificial blood: probably mechanism of adverse pulmonary reactions in treated patients and rationale for corticosteroid prophylaxis,” Blood 59(1982):1299-1304.

1384. V.V. Tuliani, E.A. O’Rear, B.M. Fung, B.D. Sierra, “Interaction between erythrocytes and a perfluorochemical blood substitute,” J. Biomed. Mater. Res. 22(January 1988):45-61.

1385. H.H. Hong, T.R. Devereux, J.H. Roycroft, G.A. Boorman, R.C. Sills, “Frequency of ras mutations in liver neoplasms from B6C3F1 mice exposed to tetrafluoroethylene for two years,” Toxicol. Pathol. 26(September-October 1998):646-650.

1386. R. Naito, K. Yokoyama, Perfluorochemical Blood Substitutes. Technical Information Series no5 and no7, Gress Cross Corp., Osaka, Japan, 1978, 1981; see also Fluosol 20% Intravascular Perfluorochemical Emulsion, Product Monograph, Alpha Therapeutic Corporation, 1990.

1387. M.P. Krafft, J.G. Riess, “Highly fluorinated amphiphiles and colloidal systems, and their applications in the biomedical field: A contribution,” Biochimie 80(May/June 1998):489-514.

1388. B. Netterstrom, “Teflon fever – a differential diagnosis of acute fever,” Ugeskr. Laeger. 155(25 January 1993):246-247. In Danish.

1389. N. Kossovsky, D. Millett, S. Juma, N. Little, P.C. Briggs, S. Raz, E. Berg, “In vivo characterization of the inflammatory properties of poly(tetrafluoroethylene) particulates,” J. Biomed. Mater. Res. 25(October 1991):1287-1301; published erratum at J. Biomed. Mater. Res. 26(February 1992):269.

1390. J.C. Ellis, T.V. McCaffrey, L.W. DeSanto, H.V. Reiman, “Migration of Teflon after vocal cord injection,” Otolaryngol. Head Neck Surg. 96(January 1987):63-66.

1391. H.J. Altermatt, J.O. Gebbers, W. Arnold, J.A. Laissue, “Phagocytosis and transport of injected teflon paste. An animal experiment study,” Laryngol. Rhinol. Otol. (Stuttg.) 65(October 1986):570-574. In German.

1392. H. Miyakita, D.S. O’Briain, P. Puri, “Absence of brain parenchymal damage following intravascular injection of polytetrafluoroethylene paste,” Eur. Urol. 34(September 1998):233-236.

1393. V. Petrozza, F. Carpino, M. Ricci, C. Anceschi, M. Melis, “Structural and ultrastructural modifications following transurethral injection of teflon paste,” Histol. Histopathol. 3(July 1988):279-282.

1394. H. Miyakita, P. Puri, “Particles found in lung and brain following subureteral injection of polytetrafluoroethylene paste are not teflon particles,” J. Urol. 152(August 1994):636-640.

1395. G. Lemperle, H. Hohler, “Granuloma after subcutaneous injection of facial wrinkles with Teflon paste,” Plastische und Wiederherstellungs-Chirurgie (19 April 1976):335-339. In German.

1396. B. Daicker, J.M. Piffaretti, E. Hafliger, J. Schipper, “Iatrogenic teflon granuloma of the eyelid,” Klin. Monatsbl. Augenheilkd. 186(February 1985):121-123. In German.

1397. D.P. Smith, B.E. Beegle, H.N. Noe, E.A. Wilson, “Does technique or material used affect bladder tissue reactions when injecting teflon or silicone paste?” Urology 48(July 1996):119-123.

1398. S. Brown, R.J. Stewart, M.D. O’Hara, C.M. Hill, “Histological changes following submucosal Teflon injection in the bladder,” J. Pediatr. Surg. 26(May 1991):546-547.

1399. P. Puri, B. O’Donnell, “Correction of experimentally produced vesicoureteric reflux in the piglet by intravesical injection of Teflon,” Br. Med. J. (Clin. Res. Ed.) 289(7 July 1984):5-7.

 