Nanomedicine, Volume IIA: Biocompatibility

© 2003 Robert A. Freitas Jr. All Rights Reserved.

Robert A. Freitas Jr., Nanomedicine, Volume IIA: Biocompatibility, Landes Bioscience, Georgetown, TX, 2003


 

References 1400-1499

1400. M.D. Gore, S.K. Fernbach, J.S. Donaldson, A. Shkolnik, M.R. Zaontz, W.E. Kaplan, “Radiographic evaluation of subureteric injection of teflon to correct vesicoureteral reflux,” AJR Am. J. Roentgenol. 152(January 1989):115-119.

1401. M. Vandenbossche, O. Delhove, P. Dumortier, F. Deneft, C.C. Schulman, “Endoscopic treatment of reflux: experimental study and review of Teflon and collagen,” Eur. Urol. 23(1993):386-393.

1402. R. Borgatti, A. Tettamanti, P. Piccinelli, “Brain injury in a healthy child one year after periureteral injection of Teflon,” Pediatrics 98(August 1996):290-291.

1403. I.A. Aaronson, R.A. Rames, W.B. Greene, L.G. Walsh, U.A. Hasal, P.D. Garen, “Endoscopic treatment of reflux: migration of Teflon to the lungs and brain,” Eur. Urol. 23(1993):394-399.

1404. H.J. Altermatt, J.O. Gebbers, A. Sommerhalder, K. Vrticka, “Histopathologic findings in the posterior pharyngeal wall 8 years after treatment of velar insufficiency with Teflon injection,” Laryngol. Rhinol. Otol. (Stuttg.) 64(November 1985):582-585. In German.

1405. A. Shafik, “Polytetrafluoroethylene injection for the treatment of partial fecal incontinence,” Int. Surg. 78(April-June 1993):159-161.

1406. Michell J. Sienko, Robert A. Plane, Chemistry, Second Edition, McGraw-Hill Book Company, New York, 1961.

1407. T.T. Ton-That, D. Doron, B.S. Pollard, J. Bacher, H.B. Pollard, “In vivo bypass of hemophilia A coagulation defect by Factor XIIa implant,” Nat. Biotechnol. 18(March 2000):289-295.

1408. H. Kahn, M.A. Huff, A.H. Heuer, “The TiNi shape-memory alloy and its applications for MEMs,” J. Micromech. Microeng. 8(1998):213-221.

1409. M. Tabib-Azar, B. Sutapun, M. Huff, “Applications of TiNi thin film shape memory alloys in micro-opto-electro-mechanical systems,” Sensors Actuators 77(1999):34-38.

1410. D.S. Grummon, L. Hou, Z. Zhao, T.J. Pence, “Progress on sputter-deposited thermoactive titanium-nickel films,” J. Physique Coll. IV 5(December 1995):665-670.

1411. Quanmin Su, S.Z. Hua, M. Wuttig, “Martensitic transformation in Ni50Ti50 films,” J. Alloys Compounds 211/212(September 1994):460-463.

1412. T. Kuninori, E. Sukedai, H. Hashimoto, “Martensitic transformation in thin foil specimen of a shape memory TiNi alloy,” Mater. Trans. JIM 37(July 1996):1404-1407.

1413. Richard H. Wolf, Arthur H. Heuer, “TiNi (Shape Memory) Films on Silicon for MEMS Applications,” J. Microelectromech. Syst. 4(1995):206-212.

1414. S. Stemmer, G. Duscher, C. Scheu, M. Ruhle, A.H. Heuer et al, “The reaction between a TiNi shape memory thin film and silicon,” J. Mater. Res. 12(July 1997):1734-1740.

1415. K.M. Knowles, D.A. Smith, “The crystallography of the martensitic transformation in equiatomic nickel-titanium,” Acta Metall. 29(1981):101-110.

1416. Y. Kudoh, M. Tokonami, S. Miyazaki, K. Otsuka, “Crystal structure of the mertensite in Ti – 49.2 at. % Ni alloy analyzed by the single crystal X-ray diffraction method,” Acta Metall. 33(November 1985):2049-2056.

1417. Ian W. Hunter, Serge Lafontaine, John M. Hollerbach, Peter J. Hunter, “Fast Reversible NiTi Fibers For Use In MicroRobotics,” MEMS-4, 1991, pp. 166-170.

1418. Paul Frenger, “Contractile Wire Biomechanical Actuators,” ISA, Paper #92-0111, 1992, pp. 9-13.

1419. Peter Krulevitch, Abraham P. Lee, Philip B. Ramsey, James C. Trevino, Julie Hamilton, M. Allen Northrup, “Thin Film Shape Memory Alloy Microactuators,” J. Microelectromech. Syst. 5(December 1996):270-281.

1420. A.D. Johnson, “Vacuum-deposited TiNi shape memory film: characterization and applications in microdevices,” J. Micromech. Microeng. 1(March 1991):34-41.

1421. A.D. Johnson, J.D. Busch, C.A. Ray, C. Sloan, “Fabrication of silicon-based shape memory alloy micro-actuators,” Mat. Res. Soc. Symp. Proc. 276(1992):151-160; J.D. Busch, A.D. Johnson, “Prototype micro-valve actuator,” IEEE Conf. Micro Electromechanical Systems, MEMS 1990, Capa, CA, 1990, pp. 40-41.

1422. S.A. Shabalovskaya, “On the nature of the biocompatibility and on medical applications of NiTi shape memory and superelastic alloys,” Biomed. Mater. Eng. 6(1996):267-289.

1423. J.L. Putters, D.M. Kaulesar, G.R. de Zeeuw, “Comparative cell culture effects of shape memory metal (Nitinol), nickel and titanium: a biocompatibility estimation,” Eur. Surg. Res. 24(1992):378-382.

1424. R. Qin, S. Peng, X. Jiang, “Morphological transformation of BHK-21 cells by nickel titanium shape memory alloy particles encapsulated by titanium oxide,” Chung Hua I Hsueh Tsa Chih 75(November 1995):663-665, 708-709. In Chinese.

1425. L.S. Castleman, S.M. Motzkin, F.P. Alicandri, V.L. Bonawit, “Biocompatibility of nitinol alloy as an implant material,” J. Biomed. Mater. Res. 10(September 1976):695-731.

1426. J. Ryhanen, E. Niemi, W. Serlo, E. Niemela, P. Sandvik, H. Pernu, T. Salo, “Biocompatibility of nickel-titanium shape memory metal and its corrosion behavior in human cell cultures,” J. Biomed. Mater. Res. 35(15 June 1997):451-457.

1427. H. Funakubo, Shape Memory Alloys, Gordon and Breach, New York, 1984 (translated by J.B. Kennedy).

1428. F.J. Gil, J.A. Planell, C. Libenson, “Differences ub tge pseudoelasticity behavior of nickel-titanium orthodontic wires,” J. Mater. Sci.: Mater. Med. 4(May 1993):281-284.

1429. P. Filip, J. Musialek, H. Lorethova, J. Nieslanik, K. Mazanec, “TiNi shape memory clamps with optimized structure parameters,” J. Mater. Sci.: Mater. Med. 7(November 1996):657-663.

1430. S. Leclercq, C. Lexcellent, J.C. Gelin, “A finite element calculation for the design of devices made of shape memory alloys,” J. Physique Coll. IV 6(January 1996):225-234.

1431. T.W. Duerig, “Present and future applications of shape memory and superelastic materials,” Proc. Mater. Res. Soc. Symp., Materials Research Society, Pittsburgh, PA, Vol. 360, 1995, pp. 497-506.

1432. G. Lim, K. Park, M. Sugihara, K. Minami, M. Esashi, “Future of active catheters,” Sensors Actuators A 56(August 1996):113-121; Yoichi Haga, Masayoshi Esashi, Shigeo Maeda, “Bending, Torsional and Extending Active Catheter Assembled Using Electroplating,” 13th Annual International Conference on Micro Electro Mechanical Systems (MEMS 2000), IEEE, 2000, pp. 181-186.

1433. S. Rhalmi, M. Odin, M. Assad, M. Tabrizian, C.H. Rivard, L.H. Yahia, “Hard, soft tissue and in vitro cell response to porous nickel-titanium: a biocompatibility evaluation,” Biomed. Mater. Eng. 9(1999):151-162.

1434. S.J. Simske, R. Sachdeva, “Cranial bone apposition and ingrowth in a porous nickel-titanium implant,” J. Biomed. Mater. Res. 29(April 1995):527-533.

1435. J. Ryhanen, M. Kallioinen, J. Tuukkanen, J. Junila, E. Niemela, P. Sandvik, W. Serlo, “In vivo biocompatibility evaluation of nickel-titanium shape memory metal alloy: muscle and perineural tissue responses and encapsule membrane thickness,” J. Biomed. Mater. Res. 41(5 September 1998):481-488.

1436. Kenneth Todar, “Immune Defense against Microbial Pathogens,” Department of Bacteriology, University of Wisconsin-Madison, 2002; http://textbookofbacteriology.net/immune.html

1437. Kenneth Todar, “Mechanisms of Bacterial Pathogenicity: Bacterial Defense Against the Host Immune Responses,” Department of Bacteriology, University of Wisconsin-Madison, 2002; http://textbookofbacteriology.net/antiimmuno.html

1438. Francis T. Thomas, Judith M. Thomas, “Chapter 21. Immunomodulation of Islet Transplantation: Future Prospects,” in Robert P. Lanza, Robert Langer, William L. Chick, eds., Principles of Tissue Engineering, R.G. Landes Company, Georgetown TX, 1997, pp. 309-322.

1439. Trevor Lyons, “The Microbiology of Periodontal Infections, Oral and Systemic Implications. The Case for the Pathogenicity of the Oral Protozoa”; http://www.magma.ca/~amoeba/egingiva.htm. See also: Trevor Lyons, Eleanor Stanfield, Introduction to Protozoa and Fungi in Periodontal Infections, Canadian Dental Association Library, ISBN 0-9693950-0-0; http://www.magma.ca/~amoeba/ISBN%209693950.htm

1440. X.M. He, D.C. Carter, “Atomic structure and chemistry of human serum albumin,” Nature 358(1992):209-215.

1441. J.R. Olivieri, A.F. Craievich, “The subdomain structure of human serum albumin in solution under different pH conditions studied by small angle X-ray scattering,” Eur. Biophys. J. 24(1995):77-84.

1442. Leo Vroman, Ann L. Adams, “Adsorption of proteins out of plasma and solution in narrow spaces,” J. Coll. Inter. Sci. 111(1986):391-402.

1443. Margaret V. Merritt, Milan Mrksich, George M. Whitesides, “Chapter 15. Using Self-Assembled Monolayers to Study the Interactins of Man-Made Materials with Proteins,” in Robert P. Lanza, Robert Langer, William L. Chick, eds., Principles of Tissue Engineering, R.G. Landes Company, Georgetown TX, 1997, pp. 211-223.

1444. E. Kerosuo, M. Haapasalo, K. Alli, K. Lounatmaa, “Ingestion of Bacteroides buccae, Bacteroides oris, Porphyromonas gingivalis, and Fusobacterium nucleatum by human polymorphonuclear leukocytes in vitro,” Oral Microbiol. Immunol. 5(August 1990):202-207.

1445. R. Podschun, I. Penner, U. Ullmann, “Interaction of Klebsiella capsule type 7 with human polymorphonuclear leucocytes,” Microb. Pathog. 13(November 1992):371-379.

1446. J. Rodgers, F. Phillips, C. Olliff, “The effects of extracellular slime from Staphylococcus epidermidis on phagocytic ingestion and killing,” FEMS Immunol. Med. Microbiol. 9(August 1994):109-115.

1447. L.F. Calvinho, R.A. Almeida, S.P. Oliver, “Influence of Streptococcus dysgalactiae surface hydrophobicity on adherence to mammary epithelial cells and phagocytosis by mammary macrophages,” Zentralbl. Veterinarmed. [B] 43(July 1996):257-266.

1448. H. Tsuda, Y. Yamashita, K. Toyoshima, N. Yamaguchi, T. Oho, Y. Nakano, K. Nagata, T. Koga, “Role of serotype-specific polysaccharide in the resistance of Streptococcus mutans to phagocytosis by human polymorphonuclear leukocytes,” Infect. Immun. 68(February 2000):644-650.

1449. H. Okada, H. Toguchi, “Biodegradable microspheres in drug delivery,” Crit. Rev. Therapeut. Drug Carrier Syst. 12(1995):1-99.

1450. P. Quellec, R. Gref, P. Calvo, M.J. Alonso, E. Dellacherie, “Encapsulation of a model protein and of a hydrophobic drug into long-circulating biodegradable nanospheres,” Proc. Int. Symp. Controlled Release Bioactive Mater. 23(1996):815-816; Ruxandra Gref, Yoshiharu Minamitake, Maria Teresa Peracchia, Vladimir Trubetskoy, Vladimir Torchilin, Robert Langer, “Biodegradable long-circulating polymeric nanospheres,” Science 263(18 March 1994):1600-1603.

1451. M.D. Blanco, M.J. Alonso, “Development and characterization of protein-loaded poly(lactide-co-glycolide) nanospheres,” Eur. J. Pharmacol. Biopharm. 43(1997):287-294.

1452. M. Tobio, R. Gref, A. Sanchez, R. Langer, M.J. Alonso, “Stealth PLA-PEG nanoparticles as nasal protein delivery systems,” Pharm. Res. 15(1998):274-279.

1453. P. Quellec, R. Gref, L. Perrin, E. Dellacherie, F. Sommer, J.M. Verbavatz, M.J. Alonso, “Protein encapsulation within polyethylene glycol-coated nanospheres. I. Physicochemical characterization,” J. Biomed. Mater. 42(1998):45-54.

1454. N.P. Desai, J.A. Hubbell, “Biological responses to polyethylene oxide modified polyethylene terephthalate surfaces,” J. Biomed. Mater. Res. 25(1991):829-843.

1455. J.M. Harris, ed., Poly(ethylene glycol) Chemistry – Biotechnical and Biomedical Applications, Plenum Press, New York, 1992.

1456. E.W. Merrill, “Poly(ethylene oxide) star molecules: synthesis, characterization, and applications in medicine and biology,” J. Biomater. Sci. Polymer Ed. 5(1993):1-11.

1457. L.G. Cima, “Polymer substrates for controlled biological interactions,” J. Cell. Biochem. 56(1994):155-161.

1458. P.D. Drumheller, J.A. Hubbell, “Densely crosslinked polymer networks of poly(ethylene glycol) in trimethylolpropane triacrylate for cell-adhesion-resistant surfaces,” J. Biomed. Mater. Res. 29(February 1995):207-215.

1459. S. Jo, K. Park, “Surface modification using silanated poly(ethylene glycol)s,” Biomaterials 21(March 2000):605-616.

1460. W.R. Gombotz, G.H. Wang, T.A. Horbett, A.S. Hoffman, “Protein adsorption to poly(ethylene oxide) surfaces,” J. Biomed. Mater. Res. 25(December 1991):1547-1562.

1461. M. Amiji, K. Park, “Prevention of protein adsorption and pletelet adhesion on surfaces by PEO-PPO-PEO triblock copolymers,” Biomaterials 13(1992):682-692.

1462. K.L. Prime, G.M. Whitesides, “Adsorption of proteins onto surfaces containing end-attached oligo(ethylene oxide): A model system using self-assembled monolayers,” J. Am. Chem. Soc. 115(1993):10714-10721.

1463. M. Amija, K. Park, “Surface modification of polymeric biomaterials with poly(ethylene oxide). A steric repulsion approach,” in W.S. Salaby, Y. Ikada, R. Langer, et al, eds., Polymers of Biological and Biomedical Significance, ACS Symposium Series 540, Washington DC, 1994, pp. 135-146.

1464. R.J. Green, M.C. Davies, C.J. Roberts, S.J.B. Tendler, “A surface plasmon resonance study of albumin adsorption to PEO-PPO-PEO triblock copolymers,” J. Biomed. Mater. Res. 42(1998):165-171.

1465. J. Folkman, A. Moscona, “Role of cell shape in growth control,” Nature 273(1978):345-349.

1466. T.W. Minett, B.J. Tighe, M.J. Lydon, D.A. Rees, “Requirements for cell spreading on polyHEMA coated culture substrates,” Cell Biol. Int. Rep. 8(February 1984):151-159.

1467. Jeffrey S. Burmeister, Valerie Z. McKinney, William M. Reichert, George A. Truskey, “Role of endothelial cell-substrate contact area and fibronectin-receptor affinity in cell adhesion to HEMA/EMA copolymers,” J. Biomed. Mater. Res. 47(1999):577-584.

1468. Milan Mrksich, George B. Sigal, George M. Whitesides, “Surface plasmon resonance permits in situ measurement of protein adsorption on self-assembled monolayers of alkanethiolates on gold,” Langmuir 11(November 1995):4383-4385.

1469. S.I. Jeon, J.H. Lee, J.D. Andrade, P.G. DeGennes, “Protein-surface interactions in the presence of polyethylene oxide: simplified theory,” J. Coll. Inter. Sci. 142(1991):149-158.

1470. P.D. Drumheller, J.A. Hubbell, “Polymer networks with grafted cell adhesion peptides for highly biospecific cell adhesive surfaces,” Analytic Biochem. 222(1994):380-388.

1471. G. Storm, S.O. Belliot, T. Daemen, D.D. Lasic, “Surface modification of nanoparticles to oppose uptake by the mononuclear phagocyte system,” Adv. Drug Deliv. Rev. 17(1995):31-48.

1472. D. Hu, H. Liu, I. Pan, “Inhibition of bovine serum albumin adsorption by poly(ethylene glycol) soft segment in biodegradable poly(ethylene glycol)/poly(L-lactide) copolymers,” J. Appl. Polym. Sci. 50(1993):1391-1396.

1473. T. Verrecchia, P. Huve, D. Bazile, M. Veillard, G. Spenlehauer, P. Couvreur, “Adsorption/desorption of human serum albumin at the surface of poly(lactic acid) nanoparticles prepared by a solvent evaporation process,” J. Biomed. Mater. Res. 27(1993):1019-1028.

1474. P. Quellec, R. Gref, E. Dellacherie, F. Sommer, M.D. Tran, M.J. Alonso, “Protein encapsulation within poly(ethylene glycol)-coated nanospheres. II. Controlled release properties,” J. Biomed. Mater. 47(1999):388-395.

1475. E. Osterberg et al, “Protein-rejecting ability of surface bound dextran in end-on and side-on configurations: Comparison to PEG,” J. Biomed. Mater. Res. 29(1995):741-747.

1476. H.-G. Hong, M. Jiang, S.G. Sligar, et al, “Cysteine-specific surface tethering of genetically engineered cytochromes for fabrication of metalloprotein nanostructures,” Langmuir 10(1994):153-158.

1477. R.D. MacGregor, C.A. Hunt, “Artificial red cells: a link between the membrane skeleton and RES detectability?” Biomaterials Art. Cells Art. Organs 18(1990):329-343.

1478. N.M. Wassef, G.R. Matyas, C.R. Alving, “Complement-dependent phagocytosis of liposomes by macrophages: suppressive effects of `stealth’ lipids,” Biochem. Biophys. Res. Commun. 176(30 April 1991):866-874.

1479. T.M. Allen, C. Hansen, “Pharmacokinetics of stealth versus conventional liposomes: effect of dose,” Biochim. Biophys. Acta 1068(30 September 1991):133-141.

1480. G.T. Colbern, D.J. Dykes, C. Engbers, R. Musterer, A. Hiller, E. Pegg, R. Saville, S. Weng, M. Luzzio, P. Uster, M. Amantea, P.K. Working, “Encapsulation of the topoisomerase I inhibitor GL147211C in pegylated (STEALTH) liposomes: pharmacokinetics and antitumor activity in HT29 colon tumor xenografts,” Clin. Cancer Res. 4(December 1998):3077-3082.

1481. J. Vaage, D. Donovan, E. Wipff, R. Abra, G. Colbern, P. Uster, P. Working, “Therapy of a xenografted human colonic carcinoma using cisplatin or doxorubicin encapsulated in long-circulating pegylated stealth liposomes,” Int. J. Cancer 80(5 January 1999):134-137.

1482. D.D. Lasic, D. Needham, “ ,”Chem. Rev. 95(1995):2601-2628; D. Needham, T.J. McIntosh, D.D. Lasic, “Repulsive interactions and mechanical stability of polymer-grafted lipid membranes,” Biochim. Biophys. Acta 1108(8 July 1992):40-48.

1483. H. Du, P. Chandaroy, S.W. Hui, “Grafted poly-(ethylene glycol) on lipid surfaces inhibits protein adsorption and cell adhesion,” Biochim. Biophys. Acta 1326(12 June 1997):236-248.

1484. N. Kossovsky, A. Gelman, E. Sponsler, “Cross linking encapsulated hemoglobin with solid phase supports: lipid enveloped hemoglobin adsorbed to surface modified ceramic particles exhibit physiological oxygen lability,” Artif. Cells Blood. Substit. Immobil. Biotechnol. 22(1994):479-485.

1485. Viola Vogel, “Molecularly Engineered Stealth Surfaces,” Department of Bioengineering, University of Washington Engineered Biomaterials (UWEB), 25 June 1998; http://www.uweb.engr.washington.edu/uweb/research/projects/vogel.html

1486. T. Horbett, M. Schway, B. Ratner, “Hydrophilic-hydrophobic copolymers as cell substrates: Effects on 3T3 cell growth rates,” J. Colloid Interface Sci. 104(1985):28-39.

1487. J. Chinn, T. Horbett, B. Ratner, M. Schway, Y. Haque, S. Hauschka, “Enhancement of serum fibronectin adsorption and the clonal plating efficiencies of swiss mouse 3T3 fibroblast and MM14 mouse myoblast cells on polymer substrates modified by radiofrequency plasma deposition,” J. Colloid Interface Sci. 127(1989):67-87.

1488. D.K. Pettit, A.S. Hoffman, T.A. Horbett, “Correlation between corneal epithelial cell outgrowth and monoclonal antibody binding to the cell binding domain of adsorbed fibronectin,” J. Biomed. Mater. Res. 28(1994):685-691.

1489. A.L. Calof, A.D. Lander, “Relationship between neuronal migration and cell-substratum adhesion: laminin and merosin promote olfactory neuronal migration but are antiadhesive,” J. Cell Biol. 115(1991):779-794.

1490. P.A. DeMilla, J.A. Stone, J.A. Quinn, S.M. Albelda, D.A. Lauffenburger, “Maximal migration of human smooth muscle cells on fibronectin and type IV collagen occurs at an intermediate attachment strength,” J. Cell Biol. 122(1993):729-737.

1491. W. Mark Saltzman, “Chapter 16. Cell Interactions with Polymers,” in Robert P. Lanza, Robert Langer, William L. Chick, eds., Principles of Tissue Engineering, R.G. Landes Company, Georgetown TX, 1997, pp. 225-246.

1492. D.A. Lauffenburger, J.J. Linderman, Receptors: Models for Binding, Trafficking, and Signaling, Oxford University Press, New Ork, 1993.

1493. E. Evans, D. Berk, A. Leung, “Detachment of agglutinin-bonded red blood cells. I. Forces to rupture molecular-point attachments,” Biophys. J. 59(April 1991):838-848; E. Evans, D. Berk, A. Leung, N. Mohandas, “Detachment of agglutinin-bonded red blood cells. II. Mechanical energies to separate large contact areas,” Biophys. J. 59(April 1991):849-860.

1494. Michael D. Ward, Micah Dembo, Daniel A. Hammer, “Kinetics of Cell Detachment: Effect of Ligand Density,” Annals Biomed. Eng. 23(1995):322-331.

1495. T.G. Ruardy, J.M. Schakenraad, H.C. van der Mei, H.J. Busscher, “Preparation and characterization of chemical gradient surfaces and their application for the study of cellular interaction phenomena,” Surf. Sci. Reports 29(1997):1-30.

1496. A. Curtis, J. Forrester, C. McInnes, F. Lawrie, “Adhesion of cells to polystyrene surfaces,” J. Cell Biol. 97(1983):1500-1506.

1497. M. Lydon, T. Minett, B. Tighe, “Cellular interactions with synthetic polymer surfaces in culture,” Biomaterials 6(1985):396-402.

1498. H.M. Kowalczynska, J. Kaminski, “Adhesion of L1210 cells to modified styrene copolymer surfaces in the presence of serum,” J. Cell Sci. 99(1991):587-593.

1499. J. Chinn, T. Horbett, B. Ratner, M. Schway, Y. Haque, S. Hauschka, “Enhancement of serum fibronectin adsorption and the clonal plating efficiencies of swiss mouse 3T3 fibroblast and MM14 mouse myoblast cells on polymer substrates modified by radiofrequency plasma deposition,” J. Colloid Interface Sci. 127(1989):67-87.

 


Last updated on 16 April 2004